8.5x11 Catalog

Reactors - Line and Load - 3 Phase - 480 Volt

Item #

Description

Open $70.00 $ 80 .00 $ 100 .00 $10 5 .00 $1 30 .00 $16 5 .00 $195.00 $205.00 $25 5 .00 $31 5 .00 $335.00 $360.00 $4 80 .00 $555.00 $6 60 .00 $77 5 .00 $890.00

Nema 1 $ 90 .00 $ 100 .00 $120.00 $1 30 .00 $16 5 .00 $20 5 .00 $24 5 .00 $2 60 .00 $31 5 .00 $3 90 .00 $4 20 .00 $4 50 .00 $ 600 .00 $69 5 .00 $82 5 .00 $96 5 .00

Nema 3R $110.00 $12 5 .00 $150.00 $160.00 $20 5 .00 $25 5 .00 $305.00 $320.00 $39 5 .00 $4 90 .00 $52 5 .00 $56 5 .00 $7 50 .00 $8 70 .00 $1,0 30 .00 $1,205.00

LR1 LR2 LR5 LR7

1 HP, Reactor 3 Phase 480V 2 HP, Reactor 3 Phase 480V 5 HP, Reactor 3 Phase 480V 7 HP, Reactor 3 Phase 480V 10 HP, Reactor 3 Phase 480V 15 HP, Reactor 3 Phase 480V 20 HP, Reactor 3 Phase 480V 25 HP, Reactor 3 Phase 480V 30 HP, Reactor 3 Phase 480V 40 HP, Reactor 3 Phase 480V 50 HP, Reactor 3 Phase 480V 60 HP, Reactor 3 Phase 480V 75 HP, Reactor 3 Phase 480V 100 HP, Reactor 3 Phase 480V 125 HP, Reactor 3 Phase 480V 150 HP, Reactor 3 Phase 480V 200 HP, Reactor 3 Phase 480V 250 HP, Reactor 3 Phase 480V 300 HP, Reactor 3 Phase 480V 350 HP, Reactor 3 Phase 480V 400 HP, Reactor 3 Phase 480V 450 HP, Reactor 3 Phase 480V 500 HP, Reactor 3 Phase 480V

LR10 LR15 LR20 LR25 LR30 LR40 LR50 LR60 LR75

LR100 LR125 LR150 LR200 LR250 LR300 LR350 LR400 LR450 LR500

$1,11 5 .00 $1,39 5 .00 $1,3 50 .00 $1,6 90 .00 $1, 400 .00 $1,7 50 .00 $1,6 80 .00 $2, 100 .00 $1,76 5 .00 $2,20 5 .00 $2,2 20 .00 $2,7 70 .00

$1,0 80 .00 $1,1 20 .00 $1,34 5 .00 $1,410.00 $1,77 5 .00 $2,2 60 .00

$2,820.00 $3,52 5 .00 All pricing is for 3% reactors, reactors rated at 5% are also available. Size the line reactor for the total amp draw of load x 1.25. Round up. Size line reactor for groups of VFD’s for total load x 1.25. Round up. (1) line reactor can be used for the group. Reactors used on line side of a VFD provide noise reduction from the drive, and provide protection for the VFD from incoming power. Load side provide protection for the motor. Some VFD’s come with internal noise reduction, but this will not protect the VFD from some supply power anomalies. Size line reactor for the total amp draw of load x 1.25. Round up. (1) line reactor can be used for the group. VFD and Motor Protection Accessories: VFD(Variable Frequency Drives) are used instead of standard starters for various reasons. The most common being for speed control but others for larger motors providing cost savings and power savings for the customer and also provides benefits for consumption on the Power Co. supply side. A VFD can cause noise on the power system. To control the excess noise that could be harmful to other equipment on the electric system, (computers, PLC’s, telecom systems, and other VFD drives), filters can be used. If the electrical system is 10x the kva rating of the VFD, then filters are required. Some VFD have built in EMC (electromagnetic capability) filters. These will act the same as a line side filter, but they may not be large enough for the application, it is suggest to still provide a separate external line side filter for the best protection.

67

Made with FlippingBook - professional solution for displaying marketing and sales documents online